(9 intermediate revisions not shown) | |||
Line 4: | Line 4: | ||
<tr><td colspan="3"><img alt="" src="/mediawiki/uploads/8/8d/Img_blank1.jpg" width="38" height="38"></td></tr> | <tr><td colspan="3"><img alt="" src="/mediawiki/uploads/8/8d/Img_blank1.jpg" width="38" height="38"></td></tr> | ||
<tr><td width="131"></td> | <tr><td width="131"></td> | ||
- | <td width=769"> | + | <td width="769"> |
- | <table width="100%" cellspacing=0 cellpadding=0 border= | + | <table width="100%" cellspacing=0 cellpadding=0 border=0> |
<tr><td><img src="/mediawiki/uploads/9/99/06_title.jpg"></td></tr> | <tr><td><img src="/mediawiki/uploads/9/99/06_title.jpg"></td></tr> | ||
<tr><td height=30> </td><td colspan=22 width="60"> </td></tr> | <tr><td height=30> </td><td colspan=22 width="60"> </td></tr> | ||
<tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">molecule to cognition med probe</span></td></tr> | <tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">molecule to cognition med probe</span></td></tr> | ||
- | <tr><td height= | + | <tr><td height=20> </td><td rowspan=20 width=35><img src="/mediawiki/uploads/5/5a/Blank2.gif"></td></tr> |
- | <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px">MED64 system available for the multiarray recording equipment brain slices or cultured nerve cells pass signals up to 64 channels | + | <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px;text-align:justify">MED64 system available for the multiarray recording equipment brain slices or cultured nerve cells pass signals up to 64 channels |
at once in the recording can be. The advantages of this equipment that can not be any other recording system in the brain slices | at once in the recording can be. The advantages of this equipment that can not be any other recording system in the brain slices | ||
in the circuit is useful for research. </td></tr> | in the circuit is useful for research. </td></tr> | ||
+ | <tr><td height=20> </td></tr> | ||
<tr><td height=30><img src="/mediawiki/uploads/8/8f/06_img01.jpg" alt=""></td></tr> | <tr><td height=30><img src="/mediawiki/uploads/8/8f/06_img01.jpg" alt=""></td></tr> | ||
<tr><td height=50> </td></tr> | <tr><td height=50> </td></tr> | ||
<tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">SYSTEM & COGNITIVE fMRI · EYE TRACKER</span></td></tr> | <tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">SYSTEM & COGNITIVE fMRI · EYE TRACKER</span></td></tr> | ||
- | <tr><td height= | + | <tr><td height=20> </td></tr> |
- | <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px">State-of-the-art 3T MRI machine (Siemens MAGNETOM Trio, A Tim System 3T with 12 and 32-channel coil) allows us to measure | + | <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px;text-align:justify">State-of-the-art 3T MRI machine (Siemens MAGNETOM Trio, A Tim System 3T with 12 and 32-channel coil) allows us to measure |
human brain activity underlying various sensory, motor, perceptual, and cognitive behaviors. In addition, high-resolution MR-compatible | human brain activity underlying various sensory, motor, perceptual, and cognitive behaviors. In addition, high-resolution MR-compatible | ||
visual stimulation goggle with eye tracking and response recording devices are available in our MRI center. Our MRI machine is also | visual stimulation goggle with eye tracking and response recording devices are available in our MRI center. Our MRI machine is also | ||
Line 26: | Line 27: | ||
Other facilities include 3 psychophysics rooms for visual experiment as well as an eye tracker (EyeLink 1000, SR Research) and several | Other facilities include 3 psychophysics rooms for visual experiment as well as an eye tracker (EyeLink 1000, SR Research) and several | ||
haploscopes for dichoptic visual stimulation. </td></tr> | haploscopes for dichoptic visual stimulation. </td></tr> | ||
+ | <tr><td height=20> </td></tr> | ||
<tr><td height=30><img src="/mediawiki/uploads/6/60/06_img02.jpg" alt=""></td></tr> | <tr><td height=30><img src="/mediawiki/uploads/6/60/06_img02.jpg" alt=""></td></tr> | ||
<tr><td height=50> </td></tr> | <tr><td height=50> </td></tr> | ||
<tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">SYSTEM & COGNITIVE STEREOTAXIC SURGERY · NEURALYNX · 8-CORE</span></td></tr> | <tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">SYSTEM & COGNITIVE STEREOTAXIC SURGERY · NEURALYNX · 8-CORE</span></td></tr> | ||
- | <tr><td height= | + | <tr><td height=20> </td></tr> |
- | <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px"> | + | <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px;text-align:justify"> |
I. Neuralynx Electrophysiological Data Acquisition System - Neuralynx cheetah system allows collecting electrophysiological signals | I. Neuralynx Electrophysiological Data Acquisition System - Neuralynx cheetah system allows collecting electrophysiological signals | ||
through multiple channels (expandable up to 1024 channels). For example, it is possible to carry out electrophysiologically recording | through multiple channels (expandable up to 1024 channels). For example, it is possible to carry out electrophysiologically recording | ||
Line 40: | Line 42: | ||
head in a multi-dimensional coordinates. For example, certain brain regions can be lesioned or electrodes can be implanted in a | head in a multi-dimensional coordinates. For example, certain brain regions can be lesioned or electrodes can be implanted in a | ||
specific brain area through stereotaxic neurosurgery.</td></tr> | specific brain area through stereotaxic neurosurgery.</td></tr> | ||
+ | <tr><td height=20> </td></tr> | ||
<tr><td height=30><img src="/mediawiki/uploads/2/2d/06_img03.jpg" alt=""></td></tr> | <tr><td height=30><img src="/mediawiki/uploads/2/2d/06_img03.jpg" alt=""></td></tr> | ||
<tr><td height=50> </td></tr> | <tr><td height=50> </td></tr> | ||
Line 45: | Line 48: | ||
<tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">CLINICAL & COMP CANTAB · EEG </span></td></tr> | <tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">CLINICAL & COMP CANTAB · EEG </span></td></tr> | ||
- | <tr><td height= | + | <tr><td height=20> </td></tr> |
- | <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px"> | + | <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px;text-align:justify"> |
CANTAB (Cambridge Neuropsychological Test Automated Battery) is a battery of validated computer-administered tests, which | CANTAB (Cambridge Neuropsychological Test Automated Battery) is a battery of validated computer-administered tests, which | ||
are developed to examine specific components of cognition, particularly those associated with frontal and medial temporal | are developed to examine specific components of cognition, particularly those associated with frontal and medial temporal | ||
regions of the brain.</td></tr> | regions of the brain.</td></tr> | ||
+ | <tr><td height=20> </td></tr> | ||
<tr><td height=30><img src="/mediawiki/uploads/4/42/06_img04.jpg" alt=""></td></tr> | <tr><td height=30><img src="/mediawiki/uploads/4/42/06_img04.jpg" alt=""></td></tr> | ||
- | <tr><td height= | + | <tr><td height=20> </td></tr> |
- | <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px"> | + | <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px;text-align:justify"> |
Dedicated to high-density EEG recordings, SynAmps is an amplifier system, consisting of 64 monopolar, 4 bipolar and 2 | Dedicated to high-density EEG recordings, SynAmps is an amplifier system, consisting of 64 monopolar, 4 bipolar and 2 | ||
high-level channels. Each channel has a dedicated 24 bit, to ensure the most accurate sampling available. Each Headbox | high-level channels. Each channel has a dedicated 24 bit, to ensure the most accurate sampling available. Each Headbox | ||
Line 59: | Line 63: | ||
elecrode positioning system consisted of 128 electrodes. Quik-Cap's highly elastic fabric provides a uniform fit over a wide | elecrode positioning system consisted of 128 electrodes. Quik-Cap's highly elastic fabric provides a uniform fit over a wide | ||
range of head size and shape variability.</td></tr> | range of head size and shape variability.</td></tr> | ||
- | <tr><td height= | + | <tr><td height=20> </td></tr> |
<tr><td height=30><img src="/mediawiki/uploads/3/3e/06_img05.jpg" alt=""></td></tr> | <tr><td height=30><img src="/mediawiki/uploads/3/3e/06_img05.jpg" alt=""></td></tr> | ||
</table> | </table> |
![]() | |||||||||||||||||||||||||||||||||||||||||||||||||||||
|