Line 17: Line 17:
     <tr><td height=20>&nbsp;</td></tr>
     <tr><td height=20>&nbsp;</td></tr>
     <tr><td height=30><img src="/mediawiki/uploads/8/8f/06_img01.jpg" alt=""></td></tr>
     <tr><td height=30><img src="/mediawiki/uploads/8/8f/06_img01.jpg" alt=""></td></tr>
-
     <tr><td height=50>&nbsp;</td></tr>
+
     <tr><td height=40>&nbsp;</td></tr>
     <tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">SYSTEM & COGNITIVE fMRI · EYE TRACKER</span></td></tr>
     <tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">SYSTEM & COGNITIVE fMRI · EYE TRACKER</span></td></tr>
-
     <tr><td height=30>&nbsp;</td></tr>
+
     <tr><td height=20>&nbsp;</td></tr>
     <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px">State-of-the-art 3T MRI machine (Siemens MAGNETOM Trio, A Tim System 3T with 12 and 32-channel coil) allows us to measure  
     <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px">State-of-the-art 3T MRI machine (Siemens MAGNETOM Trio, A Tim System 3T with 12 and 32-channel coil) allows us to measure  
human brain activity underlying various sensory, motor, perceptual, and cognitive behaviors. In addition, high-resolution MR-compatible  
human brain activity underlying various sensory, motor, perceptual, and cognitive behaviors. In addition, high-resolution MR-compatible  
Line 27: Line 27:
Other facilities include 3 psychophysics rooms for visual experiment as well as an eye tracker (EyeLink 1000, SR Research) and several  
Other facilities include 3 psychophysics rooms for visual experiment as well as an eye tracker (EyeLink 1000, SR Research) and several  
haploscopes for dichoptic visual stimulation.  </td></tr>
haploscopes for dichoptic visual stimulation.  </td></tr>
-
     <tr><td height=30>&nbsp;</td></tr>
+
     <tr><td height=20>&nbsp;</td></tr>
     <tr><td height=30><img src="/mediawiki/uploads/6/60/06_img02.jpg" alt=""></td></tr>
     <tr><td height=30><img src="/mediawiki/uploads/6/60/06_img02.jpg" alt=""></td></tr>
-
     <tr><td height=50>&nbsp;</td></tr>
+
     <tr><td height=40>&nbsp;</td></tr>
     <tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">SYSTEM & COGNITIVE STEREOTAXIC SURGERY · NEURALYNX · 8-CORE</span></td></tr>
     <tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">SYSTEM & COGNITIVE STEREOTAXIC SURGERY · NEURALYNX · 8-CORE</span></td></tr>
-
     <tr><td height=30>&nbsp;</td></tr>
+
     <tr><td height=20>&nbsp;</td></tr>
     <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px">
     <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px">
     I. Neuralynx Electrophysiological Data Acquisition System - Neuralynx cheetah system allows collecting electrophysiological signals  
     I. Neuralynx Electrophysiological Data Acquisition System - Neuralynx cheetah system allows collecting electrophysiological signals  
Line 42: Line 42:
       head in a multi-dimensional coordinates. For example, certain brain regions can be lesioned or electrodes can be implanted in a  
       head in a multi-dimensional coordinates. For example, certain brain regions can be lesioned or electrodes can be implanted in a  
       specific brain area through stereotaxic neurosurgery.</td></tr>
       specific brain area through stereotaxic neurosurgery.</td></tr>
-
     <tr><td height=30>&nbsp;</td></tr>
+
     <tr><td height=20>&nbsp;</td></tr>
     <tr><td height=30><img src="/mediawiki/uploads/2/2d/06_img03.jpg" alt=""></td></tr>
     <tr><td height=30><img src="/mediawiki/uploads/2/2d/06_img03.jpg" alt=""></td></tr>
-
     <tr><td height=50>&nbsp;</td></tr>
+
     <tr><td height=40>&nbsp;</td></tr>
     <tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">CLINICAL & COMP CANTAB · EEG </span></td></tr>
     <tr><td><span style="text-transform:uppercase;color:#000000;font-size:17px;font-family:arial;font-weight:bold">CLINICAL & COMP CANTAB · EEG </span></td></tr>
-
     <tr><td height=30>&nbsp;</td></tr>
+
     <tr><td height=20>&nbsp;</td></tr>
     <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px">
     <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px">
     CANTAB (Cambridge Neuropsychological Test Automated Battery) is a battery of validated computer-administered tests, which  
     CANTAB (Cambridge Neuropsychological Test Automated Battery) is a battery of validated computer-administered tests, which  
are developed to examine specific components of cognition, particularly those associated with frontal and medial temporal  
are developed to examine specific components of cognition, particularly those associated with frontal and medial temporal  
regions of the brain.</td></tr>
regions of the brain.</td></tr>
-
     <tr><td height=30>&nbsp;</td></tr>
+
     <tr><td height=20>&nbsp;</td></tr>
     <tr><td height=30><img src="/mediawiki/uploads/4/42/06_img04.jpg" alt=""></td></tr>
     <tr><td height=30><img src="/mediawiki/uploads/4/42/06_img04.jpg" alt=""></td></tr>
-
     <tr><td height=30>&nbsp;</td></tr>
+
     <tr><td height=20>&nbsp;</td></tr>
     <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px">
     <tr><td span style="font-family:arial;font-size:12px;color:#414141;line-height:16px">
     Dedicated to high-density EEG recordings, SynAmps is an amplifier system, consisting of 64 monopolar, 4 bipolar and 2  
     Dedicated to high-density EEG recordings, SynAmps is an amplifier system, consisting of 64 monopolar, 4 bipolar and 2  
Line 63: Line 63:
elecrode positioning system consisted of 128 electrodes. Quik-Cap's highly elastic fabric provides a uniform fit over a wide  
elecrode positioning system consisted of 128 electrodes. Quik-Cap's highly elastic fabric provides a uniform fit over a wide  
range of head size and shape variability.</td></tr>
range of head size and shape variability.</td></tr>
-
     <tr><td height=30>&nbsp;</td></tr>
+
     <tr><td height=20>&nbsp;</td></tr>
     <tr><td height=30><img src="/mediawiki/uploads/3/3e/06_img05.jpg" alt=""></td></tr>
     <tr><td height=30><img src="/mediawiki/uploads/3/3e/06_img05.jpg" alt=""></td></tr>
</table>
</table>

Revision as of 19:32, 12 September 2011

  
molecule to cognition med probe
 
MED64 system available for the multiarray recording equipment brain slices or cultured nerve cells pass signals up to 64 channels at once in the recording can be. The advantages of this equipment that can not be any other recording system in the brain slices in the circuit is useful for research.
 
 
SYSTEM & COGNITIVE fMRI · EYE TRACKER
 
State-of-the-art 3T MRI machine (Siemens MAGNETOM Trio, A Tim System 3T with 12 and 32-channel coil) allows us to measure human brain activity underlying various sensory, motor, perceptual, and cognitive behaviors. In addition, high-resolution MR-compatible visual stimulation goggle with eye tracking and response recording devices are available in our MRI center. Our MRI machine is also equipped with newly developed protocols and software including zoomed EPI and online motion correction algorithm for real-time fMRI. Other facilities include 3 psychophysics rooms for visual experiment as well as an eye tracker (EyeLink 1000, SR Research) and several haploscopes for dichoptic visual stimulation.
 
 
SYSTEM & COGNITIVE STEREOTAXIC SURGERY · NEURALYNX · 8-CORE
 
I. Neuralynx Electrophysiological Data Acquisition System - Neuralynx cheetah system allows collecting electrophysiological signals through multiple channels (expandable up to 1024 channels). For example, it is possible to carry out electrophysiologically recording multiple single unit responses simultaneously in freely behaving animals.
II. Eight-core machine - A computer with eight CPUs working in parallel with large memory capacity to analyze a large dataset such as electrophysiological dataset recorded in parallel from multiple channels.
III. Stereotaxic surgical system - Stereotaxic surgical systems are used to surgically target a specific brain region by putting the animal’s head in a multi-dimensional coordinates. For example, certain brain regions can be lesioned or electrodes can be implanted in a specific brain area through stereotaxic neurosurgery.
 
 
CLINICAL & COMP CANTAB · EEG
 
CANTAB (Cambridge Neuropsychological Test Automated Battery) is a battery of validated computer-administered tests, which are developed to examine specific components of cognition, particularly those associated with frontal and medial temporal regions of the brain.
 
 
Dedicated to high-density EEG recordings, SynAmps is an amplifier system, consisting of 64 monopolar, 4 bipolar and 2 high-level channels. Each channel has a dedicated 24 bit, to ensure the most accurate sampling available. Each Headbox consists of 70 channels, and multiple Headboxes can be linked together to build high-density systems. Inputs for high-level signals are also provided, allowing you to capture the time series data of other measures along with the EEG. Quik-Cap is an elecrode positioning system consisted of 128 electrodes. Quik-Cap's highly elastic fabric provides a uniform fit over a wide range of head size and shape variability.